A device shows "Offline"
What you see: a red Offline pill in Settings → Hardware, with last seen "never" or some hours ago. You may also get a briefing: "Device hasn't reported in 4+ hours".
Why it happens: BarrelLogic hasn't received a reading from the device in more than 60 minutes. A device that has never sent a reading shows "never".
Sensors send their readings through your cellar hub, which needs power and a network connection to pass them on.
How to fix it:
- Check the hub. Make sure your cellar hub is powered and connected to your network.
- Check the distance. Make sure the sensor is within range of the hub.
- Check the battery. If the card showed Low battery before it went offline, the battery may be flat. See below.
- Wait for the next reading. As soon as one reading arrives, the device shows Online again.
- If it's still offline after that, email hardware@barrellogic.com with the device serial and its last-seen time.
The Restart button doesn't yet reach devices, so it won't bring an offline device back. Use the steps above instead.
"Low battery"
What you see: an amber Low battery pill and battery percentage, or a briefing "Device battery at N%".
Why it happens: the battery is below 15%.
How to fix it: replace the battery. Smart bungs use a CR2477 coin cell. Batteries are consumables with their own warranty terms; see the hardware warranty.
The vessel says "No sensor installed"
No sensor installed. Add a Smart Bung or Tri-Clamp in Settings · Hardware.
Why it happens: there are no sensor readings for this vessel from the last 7 days. That covers three situations:
- no device is assigned to this vessel;
- a device is assigned, but it's been offline for 7 days or more;
- the device was assigned to this vessel recently, and its earlier readings belong to the vessel it was assigned to before.
How to fix it:
- In Settings → Hardware, find the device and check that it's assigned to this vessel. If not, click Assign and choose it.
- Check the device is Online. If it's offline, follow the steps above.
- Readings appear on the vessel as soon as the next one arrives.
"One reading so far — waiting for more."
The chart needs at least two readings to draw a line. Wait for the next one.
Readings look out of date
Check "Last 7 days · updated …" on the vessel's Live sensors panel, and the device's last-seen time in Settings → Hardware. If last seen is more than an hour ago, the device is offline; follow the steps at the top.
The device doesn't appear in Settings → Hardware at all
Devices only appear after they're activated. See Activating a sensor and assigning it to a vessel.